Apple MULTIPLE SCAN 15AV Especificaciones Pagina 26

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 142
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 25
Take Apart Safety Guidelines for Taking Apart the Apple Multiple Scan 15AV
Safety Guidelines for Taking Apart the
Apple Multiple Scan 15AV Display
±
Warning:
This product contains high voltage and a high-
vacuum picture tube. To prevent serious injury, review
CRT safety in Bulletins/Safety.
±
Warning:
Never use a grounding wriststrap until after
discharging the CRT and setting up an ongoing ground
connection.
Important:
Whenever the housing of the monitor is removed
and before replacing a module, you must
1 Discharge the CRT and remove the anode cap.
2 Establish an ongoing ground by using a cable with
alligator clips at both ends. Connect one end to the anode
aperture, and connect the other end to the braided ground
strap that wraps around the CRT.
3 With the CRT discharged and the ongoing ground in place,
wear a grounding wriststrap to prevent equipment
damage from static electricity.
Anode Cap
CRT Discharge Tool
Ongoing GroundAnode Aperture
Ground Strap
Note:
The ground strap
and CRT/video board on
newer displays are
somewhat different than
pictured here. Refer to
“Repair Issues” in the
Basics chapter for details.
Vista de pagina 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 141 142

Comentarios a estos manuales

Sin comentarios