Adjustments High Voltage - 9
5 Connect the positive
probe (red wire) of a
digital voltmeter to the
cathode (striped end) of
D713.
6 Connect the ground probe
of the digital voltmeter
(black wire) to the
monitor’s metal chassis.
7 Use a plastic
screwdriver to adjust
VR501 so that the
voltmeter reads a voltage
of 42.5 VDC ± 0.2V.
VR501
Ground Probe at
Chassis
Positive Probe at
Cathode of D713