Apple Multiple Scan 20 Display Especificaciones Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 129
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
Take Apart Safety Guidelines for Taking Apart the Apple Multiple Scan 15AV
Safety Guidelines for Taking Apart the
Apple Multiple Scan 15AV Display
±
Warning:
This product contains high voltage and a high-
vacuum picture tube. To prevent serious injury, review
CRT safety in Bulletins/Safety.
±
Warning:
Never use a grounding wriststrap until after
discharging the CRT and setting up an ongoing ground
connection.
Important:
Whenever the housing of the monitor is removed
and before replacing a module, you must
1 Discharge the CRT and remove the anode cap.
2 Establish an ongoing ground by using a cable with
alligator clips at both ends. Connect one end to the anode
aperture, and connect the other end to the braided ground
strap that wraps around the CRT.
3 With the CRT discharged and the ongoing ground in place,
wear a grounding wriststrap to prevent equipment
damage from static electricity.
Anode Cap
CRT Discharge Tool
Ongoing GroundAnode Aperture
Ground Strap
Vista de pagina 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 128 129

Comentarios a estos manuales

Sin comentarios